If needed, you can equip CI System continuous rooflight B with smoke and heat ventilation devices that fulfil the requirements of EN 12101-2. Single or double flaps, which can be actuated for normal and fair weather ventilation, are integrated to provide a smoke and heat ventilation system.


Your benefits at a glance:- Suitable as a melt-out roof surface to DIN 18230, and available as "rigid roofing" on request; DIN 4102 Part 7 resistant to flying sparks and radiated heat
- Excellent heat-insulation values
- Thermal actuation with CO2 bottles – no damage caused by tests or false alarms
For more details on CI System smoke lift B look here.
CI System smoke lift B
function: SHEVS open only, SHEVS open/ close, for ventilation
design: continuous rooflight barrel-vault shaped

| |
glazing |
frame |
flaps |
fittings |
| materials |
multi-layer PC plates 100 - 600 cm width |
aluminium/ PVC |
aluminium/ PVC |
aluminium/ stainless steel |
| fall-trough-proof during mounting as per German BG standard |
yes |
|
|
|
| hail-proof as per EMPA-norm |
yes |
|
|
|
| construction material classification |
B1/ B2 |
B2/ A1 |
B2/ A1 |
A1 |
| physics |
Ug-value = 1,5 - 2,8 W/(m²K) |
Uf-value = 1,7 - 2,7 W/(m²K) |
Uf-value<= 2,8 W/(m²K) |
|
LAMILUX upstands for continuous rooflights
function: ideal connection to the building

| material |
sheet steel |
| construction material classification |
A1 |
| DIN 18234 fulfilled without extra measurements such as graved fill |
yes |
Sizes and aerodynamic values CI System continuous rooflight B

| size |
Aw-value (in m²) |
| single flap |
|
| 120/100 |
0,78 |
| 120/200 |
1,60 |
| double flap |
|
| 150/200 |
2,01 |
| 200/200 |
2,72 |
| 250/200 |
3,44 |
| 300/200 |
4,15 |
| 150/100 |
1,11 |
| 200/100 |
1,51 |
| 250/100 |
1,79 |
| 300/100 |
2,16 |
If needed, you can equip CI System continuous rooflight S with smoke and heat ventilation devices that fulfil the requirements of EN 12101-2. Single or double flaps, which can be actuated for normal (electrical, pneumatic) and fair weather (pneumatic) ventilation, are integrated to provide a smoke and heat ventilation system.


Your benefits at a glance:- Complies with EN 12101-2
- Suitable as a melt-out area
- Good heat-insulation values
- The solution where the architecture requires a saddleback roof form
- Thermal actuation with CO2 bottles – no damage caused by tests or false alarms
For more details on CI System continuous rooflight S look here.
CI System smoke lift S
function: SHEVS open only, for ventilation
design: continuous rooflight gable roof shaped

| |
glazing |
frame |
fittings |
| material |
multi-layer PC plates |
aluminium/ PVC |
stainless steel |
| width |
125 - 400 cm width at 30° angle of inclination , 125 - 300 cm width at 45° angle of inclination |
|
|
| fall-trough-proof during mounting as per German BG standard |
yes |
|
|
| hail-proof as per EMPA-norm |
yes |
|
|
| construction material classification |
B2 (B1 on request) |
A1/ B2 |
A1 |
| physics |
Ug-value = 1,7 W/(m²K) |
|
|
LAMILUX upstands for continuous rooflights
function: ideal connection to the building

| material |
sheet steel |
| construction material classification |
A1 |
| DIN 18234 fulfilled without extra measurements such as graved fill |
yes, with additional covering plate |
Sizes and aerodynamic values CI System continuous rooflight S
| size |
Aw-value (in m²) |
| 150/I |
1,093 |
| 250/I |
1,762 |
| 150/II |
1,244 |
| 250/II |
2,005 |
| 150/III |
1,697 |
| 250/III |
2,963 |
|