CI System glass architecture M
During the development of the CI System glass architecture M the driving idea was to create a daylight system that combines a compact and extremely filigree modular construction with enormous architectural scope for a wide range of applications. No matter whether you are designing a hipped or saddleback roof, or a pyramid shape, aesthetically pleasing glass architecture and standardized components are no contradiction with this daylight system.
CI System glass architecture M supports rapid planning and assembly. Supporting constructions with an extremely filigree look, with slim-line ridge and base profiles, and the lack of cross members allows for optimum light incidence.
- Modular design for rapid planning and assembly
- Filigree supporting construction thanks to slim-line ridge and base profiles and lack of cross members
- Mature, patented heat technology system with optimized isothermal characteristics: no heat bridges at the foot of the supporting structure or in the fan blades
- Flexible assembly: extremely variable and individual customization options for topping the building shell
- Large choice of glazing variants: heat insulated glazing, combined solar and heat protection glazing, sound proof glass
- Suitable for openings of between 1.00 m and 4.00 m, continuously variable lengths of 1.00 m upwards
- Inclination angle 30°
- Saddleback, hipped roof or pyramid type possible
- Can be installed on steel jambs, concrete or wooden frames, and even on upstands for smaller dimensions
- Aluminium supporting structure
- Extras: RAL colour coating of visible aluminium components, optional ventilation function, optional smoke lift to EN 12101-2
- Service: Project management, maintenance, delivery and assembly by LAMILUX
| glazing |
light permeability in % |
total energy admission g in % as per DIN EN 410 |
Ug value W/(m²K) as per DIN EN 673 |
sound insulation in dB* |
type |
| BioClean |
76 |
63 |
1,1 |
ca. 35 |
W100 |
| Climatop triple glazing |
69 |
50 |
0,6 |
ca. 36 |
W101 |
| heat insulation glazing 1,1 ESG |
76 |
63 |
1,1 |
ca. 35 |
W102 |
| heat insulation glazing 1,1 ESG MHF |
53 |
63 |
1,1 |
ca. 35 |
W103 |
| heat insulation glazing 1,1 Float |
76 |
63 |
1,1 |
ca. 35 |
W104 |
| heat insulation glazing1,1 Float MHF |
53 |
63 |
1,1 |
ca. 35 |
W105 |
| heat insulation glazing 1,0 ESG |
68 |
44 |
1,0 |
ca. 35 |
W106 |
| heat insulation glazing 1,0 ESG MHF |
50 |
34 |
1,0 |
ca. 35 |
W107 |
| heat insulation glazing 1,0 Float |
68 |
44 |
1,0 |
ca. 35 |
W108 |
| heat insulation glazing 1,1 Float MHF |
50 |
34 |
1,0 |
ca. 35 |
W109 |
| Iso Roll (mit motorisch betätigbarem Folienrollo im Scheibenzwischenraum) |
76 |
63 |
1,3-1,6 |
ca. 40 |
S100 |
| sun and heat protective glazing 48/25 ESG |
48 |
27 |
1,1 |
ca. 35 |
S101 |
| sun and heat protective glazing 48/25 ESG MHF |
36 |
27 |
1,1 |
ca. 35 |
S102 |
| sun and heat protective glazing 48/25 Float |
48 |
27 |
1,1 |
ca. 35 |
S103 |
| sun and heat protective glazing 48/25 Float MHF |
36 |
27 |
1,1 |
ca. 35 |
S104 |
| sun and heat protective glazing 60/48 Antelio Silber ESG |
60 |
48 |
1,1 |
ca. 35 |
S105 |
| sun and heat protective glazing 60/48 Antelio Silber ESG MHF |
42 |
48 |
1,1 |
ca. 35 |
S106 |
| sun and heat protective glazing 60/48 Antelio Silber Float |
60 |
48 |
1,1 |
ca. 35 |
S107 |
| sun and heat protective glazing 60/48 Antelio Silber Float MHF |
42 |
48 |
1,1 |
ca. 35 |
S108 |
| sun and heat protective glazing 60/30 ESG |
60 |
32 |
1,1 |
ca. 35 |
S109 |
| sun and heat protective glazing 60/30 ESG MHF |
42 |
32 |
1,1 |
ca. 35 |
S110 |
| sun and heat protective glazing 60/30 Float |
60 |
32 |
1,1 |
ca. 35 |
S111 |
| sun and heat protective glazing 60/30 Float MHF |
42 |
32 |
1,1 |
ca. 35 |
S112 |
| sun and heat protective glazing 68/41 ESG |
68 |
41 |
1,2 |
ca. 35 |
S113 |
| sun and heat protective glazing 68/41 ESG MHF |
42 |
41 |
1,2 |
ca. 35 |
S114 |
| sun and heat protective glazing 68/41 Float |
68 |
41 |
1,1 |
ca. 35 |
S115 |
| sun and heat protective glazing 68/41 Float MHF |
42 |
41 |
1,1 |
ca. 35 |
S116 |
| sound insulation glazing |
77 |
56 |
1,2 |
42** |
SD42 |
* as per DIN 4109 ** as per DIN ISO 140-3
All specifications are approximate. Ug values as per DIN-EN 673 Standard versions for snow loads up to 0,75kN/m² and wind loads up to 0,8kN/m²
Light directing or light dispersing glazings are available upon request. increased snow and wind loads upon request
Solar protection with deciduous tree effect: Metal screen in any RAL coating you require with deciduous tree effect for natural shade. Deciduous tree effect screens provide protection against hail and incident UV light.
Personal protective equipment PSA: Climbing eyes for staff protection on the roof fulfil DIN EN 795 class A1 requirements and bear a BG mark.
Aluminium profiles in RAL colours: All visible aluminium profiles can be coated individually with RAL colours. Two-tone types available on request.

The CI-system combination flap M
SHEV and natural ventilation for roof or façade in a variable system designed in a compact daylight element with real glazing and best-of-breed thermal insulation. With the CI-system combination flap M LAMILUX launches an extremely compact and high-quality manufactured flap system that besides its excellent energy values already today complies with tomorrow’s European standards. After a two year introduction phase the DIN EN 14351-1 will be effected from February 2009 onwards. By this the compulsory CE-marking for roof windows, windows and exterior doors will be implemented.

Our development - your advantages:- rain proof ventilation technology with integrated SHEV-operation in one flap system
- conformity with the European standard EN 12101-2 for SHEVs
- all-purpose integrated combination frame (IKF)
- possible integration into almost all profile-systems (roof/façade) with inclination from 0 to 90 degrees
- large choice of glazing variants: heat insulated glazing (thermal transmittance value 1,7 to 0,6), combined solar and heat protection glazing, sound proof glass
Approved quality:
The CI-system combination flap M has passed extensive numbers of tests such as - resistance to wind load (class C4/B5 EN 12210)
- resistance to driving rain (class E 1200 EN 12208)
- heat protection (thermal transmittance Ug value 1,7 to 0,6 W/[m2K] EN 673)
- total energy admission (g from 18 to 78 percent)
- air permeability (class 4 EN 12207)
- grade of light transmission (Lt from 19 to 82 percent)
- noise control (EN ISO 140-3 up to 45 dB)
|