LAMILUX Continuous Rooflight: The fittings

Glazing types

  • Optimum glazing for all requirements, such as sound and heat insulation, light transmission and chemical resistance
  • Multi-layer, opaque polycarbonate panels (non-glare) offered as standard
  • Clear panels at no extra charge
  • Possible to fit Heatstop in part
  • "Hard roofing" possible, combined with melt-out surface
  • GF-UP + GF-UP glazing variations upon request

Important: Ug value is determined as per DIN EN 673 (vertical installation). The profile structure's actual heat transmission values, including those of base profiles, gable wall profiles and flap profiles, are to be used to calculate the continuous rooflight's energy values.

 

Ug value: 2,5 W/(m²K)
Sound-proofing value: 17 dB
Building material class: B-s1, d0
Translucency: ca. 61%

Ug value: 2,4 W/(m²K)
Sound-proofing value: 20 dB
Building material class: B2
Translucency: ca. 51%

Ug value: 1,8 W/(m²K)
Sound-proofing value: 17 dB
Building material class: B-s1, d0
Translucency: ca. 42%

Ug value: 1,8 W/(m²K)
Sound-proofing value: 20 dB
Building material class: B2
Translucency: ca. 36%

Ug value: 2,3 W/(m²K)
Sound-proofing value: 27 dB
Building material class: B2
Translucency: ca. 51%

 

Ug value: 1,6 W/(m²K)
Sound-proofing value: 19 dB
Building material class: B2
Translucency: ca. 39%

Ug value: 1,6 W/(m²K)
Sound-proofing value: 20 dB
Building material class: B2
Translucency: ca. 33%

Ug value: 1,4 W/(m²K)
Sound-proofing value: 17 dB
Building material class: B-s1, d0
Translucency: ca. 50%

Ug value: 1,2 W/(m²K)
Sound-proofing value: 18 dB
Building material class: B2
Translucency: ca. 39%

 

Ug value: 1,2 W/(m²K)
Sound-proofing value: 21 dB
Building material class: B2
Translucency: ca. 33%

Ug value: 1,3 W/(m²K)
Sound-proofing value: 24 dB
Building material class: B2
Translucency: ca. 36%

Ug value: 3,1 W/(m²K)
Sound-proofing value: 22 dB
Building material class: B2
Translucency: ca. 40%

Flap-systems for SHEVS and Ventilation

  • Integration as an individual flap or as flap on flap system.
  • Electric motors (24 volt/230 volt) with a spindle drive or pneumatic drive assemblies with pneumatic cylinders ensure manually-triggered or control-automated opening and closing
  • Optional: Wind and rain sensors
  • The actuation of the flap systems for natural ventilation can be automated in an energy-efficient manner
  • Optimum tightness against driving rain due to welded sealing frame with anti-splash lip and an integrated balloon gasket

Sizes CI System ventilation flap BE single flap

TypeGeometrical inlet surface Ageo
100/1000,93 m²
100/2001,96 m²
125/1001,17 m²
125/2002,46 m²
150/1001,43 m²
150/2003,01 m²

CI System Smoke Lift B

Can be supplied as single flap or as symmetric and asymmetric double flap (more info here)