LAMILUX Continuous Rooflight: The fittings

Glazing types (north light side)

  • North light side: translucent glazing; shed side with PV modules: opaque
  • Standard version features multi-shell, opal polycarbonate panels in thickness up to 32 mm
  • Highly soundproof and chemically-resistant glazing available
  • Glazing made of glass-fibre reinforced polyester is highly resistant to UV incidence and weathering
  • The blue translucent gelcoat guarantees an overall translucency of around 33 percent
  • In north light shed design: shed rear also features opaque GF-UP panel on inside

Important: Ug value is determined as per DIN EN 673 (vertical installation). The profile structure's actual heat transmission values, including those of base profiles, gable wall profiles and flap profiles, are needed to calculate the continuous rooflight's energy values.

 

 


Ug value: 2,5 W/(m²K)
Sound-proofing value: 17 dB
Building material class: B-s1, d0
Translucency: ca. 61%

 
Ug value: 2,4 W/(m²K)
Sound-proofing value: 20 dB
Building material class: B2
Translucency: ca. 51%


Ug value: 1,8 W/(m²K)
Sound-proofing value: 17 dB
Building material class: B-s1, d0
Translucency: ca. 42%

Ug value: 1,8 W/(m²K)
Sound-proofing value: 20 dB
Building material class: B2
Translucency: ca. 36%


Ug value: 1,2 W/(m²K)
Sound-proofing value: 18 dB
Building material class: B2
Translucency: ca. 38%


Ug value: 1,2 W/(m²K)
Sound-proofing value: 18 dB
Building material class: B2
Translucency: ca. 30%

Ug value: 3,1 W/(m²K)
Sound-proofing value: 22 dB
Building material class: B2
Translucency: ca. 40%

Ug value: 2,3 W/(m²K)
Sound-proofing value: 27 dB
Building material class: B2
Translucency: ca. 51%

Flap system for SHEV and ventilation

  • Integration as a single flap on the north light side
  • Opening and closing: manual or automated
  • SHEV: CI System Smoke Lift S as a single flap as per DIN EN 12101-2
  • Electric motors (24 V/230 V) with spindle drive or pneumatic drive units with pneumatic cylinders
  • Energy-efficient activation of flap systems for natural ventilation, fitted with wind and rain sensor set and additional control system components
  • Optimum water-tightness due to welded seal frame
    Optimum insulating properties
  • Extremely safe when installing the continuous rooflight as there is no need to weld separate sealing points
  • Tight sealing guaranteed for the flap system due to dimensional tolerance compensation in the balloon seal
Measure (OKD)Dimension xDimension yGeometrical inlet surface AgeoAerodynamically effective opening surface
100100530,53 m²0,32 m²
100*120530,63 m²0,38 m²
150100820,82 m²

0,49 m²

150*120820,97 m²0,58 m²
2001001111,11 m²0,64 m²
200*1201111,31 m²0,76 m²
2501001401,40 m²0,80 m²
250*1201401,65 m²0,92 m²
3001001691,69 m²0,95 m²
300*1201691,99 m²1,09 m²