Continuous Rooflight W | R by LAMILUX: Equipment options

Glazing versions

Important: Ug value is determined as per DIN EN 673 (vertical installation). The profile structure's actual heat transmission values, including those of base profiles, gable wall profiles and flap profiles, are to be used to calculate the continuous rooflight's energy values.

PC40-4

Uvalue (vertical | horizontal installation):1,5 W/(m²K) | 1,6 W/(m²K)
Sound insulation value (manufacturer information):25 dB
Max. service temperature without load:-40° to + 115 °C
UV resistance:Co-extruded, external UV protection layer
Hail resistance:Resistance class 5 (tightness)
Installed Thickness | Weight:40 mm | 4,00 kg/m²
Light transmission level (τ) (opal | clear):approx. 61% | approx. 66%
Total energy transmittance (g) (opal | clear):approx. 68% | approx. 65%



PC40-7

Uvalue (vertical | horizontal installation):1,1 W/(m²K) | 1,2 W/(m²K)
Sound insulation value (manufacturer information):24 dB
Max. service temperature without load:-40° to + 115 °C
UV resistance:Co-extruded, external UV protection layer
Hail resistance:Resistance class 5 (tightness)
Installed Thickness | Weight:40 mm | 4,30 kg/m²
Light transmission level (τ) (opal | clear):approx. 41% | approx. 53%
Total energy transmittance (g) (opal | clear):approx. 47% | approx. 56%

PC50-10

Uvalue (vertical | horizontal installation):0.87 W/(m²K) | 0.89 W/(m²K)
Sound insulation value (manufacturer information):27 dB
Max. service temperature without load:-40° to + 115 °C
UV resistance:Co-extruded, external UV protection layer
Hail resistance:Resistance class 5 (tightness)
Installed Thickness | Weight:50 mm | 5.00 kg/m²
Light transmission level (τ) (opal | clear):approx. 36% | approx. 44%
Total energy transmittance (g) (opal | clear):approx. 41% | approx. 50%

PC60-12

Uvalue (vertical | horizontal installation):0.75 W/(m²K) | 0.77 W/(m²K)
Sound insulation value (manufacturer information):27 dB
Max. service temperature without load:-40° to + 115 °C
UV resistance:Co-extruded, external UV protection layer
Hail resistance:Resistance class 5 (tightness)
Installed Thickness | Weight:60 mm | 5.80 kg/m²
Light transmission level (τ) (opal | clear):approx. 30% | approx. 41%
Total energy transmittance (g) (opal | clear):approx. 37% | approx. 43%

Panels & Frame profile

NSHEV (natural smoke and heat exhaust ventilation system) – A construction for all types of glazing (certified according to DIN EN 12101).

Size table with aerodynamically effective opening surface in m²

Width Height (mm)
(mm)

830

110014001690
10000,480,640,800,95
15000,620,811,011,21
20000,971,301,611,81
21000,931,241,541,73
42001,842,402,97